• EXHAUST GAS ANALYSER (PETROL ENGINE)

 
FOR FIVE GASES (WITH RTO APROVEL)
 
FOR FIVE GASES (WITH RTO APROVEL)
 
A. Gases detected:- CO, HC, Nox, CO2 & O2

B. Principle :- Non-Dispersive Infra – Red for CO, CO2 & HC, Electrochemical sensor for O2 & NOx

C. Range :- CO : o to 15%, HC : 0 to 30000 ppm as hexane,
O2: 0 to 25%, CO2: 0 to 20%
NOx: 0 to 5000 ppm

D. Data Resolution : CO, O2 , CO2 : 0.01% , HC & NOx : 1 ppm

E. Accuracy : + 3% relative , + 0.02% absolute

F. Display : 20 character x 4- line backlit LCD display Additional 8 mm multi colour LEC display for each gas for Distant view.

G. Keyboard : Membrane keypad with 16 keys.

H. Start-up Time : 1 min. from power ON. Full accuracy within 15 Minutes.

I. Zero Time : Less thank 30 seconds.

J. Intrinsic Response Time : 15 seconds

K. Gas flow rate : 1 l/min. ( adjustable using built-in flow meter )

L. Sample Handling System : S. S. probe, PU tubing with easily detachable connectors, water separator cum filter, disposable particulate fine filter. Flexible probe available on request.

M. Sample Extraction : With a built- in Pump

N. Other Features : Automatic fresh air intake during auto zero. Line leak checkh facility.

O. Printer : 24-column dot matrix printer ( optional )

P. Printer Out Put : CO, O2 , CO2 in % HC & NOx in ppm

Q. Rating Temperature : 5 t0 450 C

R. Power supply : 230 V + 10% 12 V Battery

S. Dimensions & Weight : 340 x 240 x 130 mm, 4 kg

 

 
FOR FOUR GASES
 
A. Gases detected :- CO, HC, CO2( by calculation)& O2 (by chemical sensor)

B. Principle :- Non-Dispersive Infra – Red

C. Range :- CO : 0 to 15%, HC : 0 to 10000 ppm,
O2 : 0 to 25%, CO2 : 0 to 20%

D. Data Resolution : CO, O2 , CO2 : 0.01% , HC : 1 ppm

E. Accuracy : + 3% relative , + 0.02% absolute

F. Display : 16 character x 2- line backlit LCD display (9mm Character dispaly) for day and night visibility.

G. Keyboard : Membrane keypad with 18 keys.

H. Start-up Time : 1 min. from power ON. Full accuracy within 15 Minutes.

I. Zero Time : Less thank 40 seconds.

J. Intrinsic Response Time : 10 seconds

K. Gas flow rate : 500cc/min. ( adjustable using built-in flow meter )

L. Sample Handling System : S. S. probe, PU tubing with easily detachable connectors, water separator cum filter, disposable particulate fine filter.

M. Printer : 24-column dot matrix printer

N. Printer Out Put : CO, in % HC in ppm (2-gas version)

O. Rating Temperature : 5 t0 450 C

P. Power supply : 230 V + 10% 12 V Battery

Q. Dimensions & Weight : 340 x 240 x 130 mm, 4 kg
 

 
SMOKE METER (DIESEL ENGINE) (WITH RTO APROVEL)
 
A. Measurement:- Smoke density in hartridge Smoke Unit (HSU) / Absorption Coefficient (K)

B. Principle :- Attenuation of light beam.

C. Range :- 0 to 100% opacity in HSU, 0 to  absorption in m-1

D. Light Source:- Halogen bulb, 12 V DC/ 20 W.

E. Colour Temperature:- 3050 K.

F. Display : 16 character backlit LCD display
i . Light absorption coefficient K in m-1
ii. Temperature in 0 C.

G. Keyboard : Membrane keypad with 18 keys.

H. Stabilization Time : 30 minutes

I. Time Constant : Physical 0 to1 second. Electrical < 1 m second.

J. Temperature Sensor: RTD, PT 100.

K. Printer : 24-column dot matrix printer

L. Probe :A probe with synthetic rubber connecting hose (4 m)

M. Operating Temperature : 0 t0 500 C

N. Power supply : 190 -250 V AC/ 11- 12 V DC

O. Power Consumption: 500 W (Overall equipment)

P. Control Unit : 340 x 240 x 130 mm, 4 Kg.

Q. Measuring Unit : 650 x 285 x 245 mm , 2 Kg.

R. Calibration: Using Calibration filters of known intensity.

S. Smoke Column Temp : 70 – 100 0 C
Heating Time : 20 min
 

 
FOR FOUR GASES (WITHOUT RTO APROVEL)
 
A. Gases detected: - CO, HC, CO2 (by calculation) & O2 (by chemical sensor)

B. Principle: - Non-Dispersive Infra – Red

C. Range: - CO: 0 to 15%, HC: 0 to 10000 ppm,
O2: 0 to 25%, CO2: 0 to 20%

D. Data Resolution: CO, O2, CO2: 0.01%, HC: 1 ppm

E. Accuracy: + 3% relative, + 0.02% absolute

F. Display: 16 character x 2- line backlit LCD display (9mm Character display) for day and night visibility.

G. Intrinsic Response Time: 10 seconds

H. Gas flow rate: 500cc/min. (adjustable using built-in flow meter)

I. Sample Handling System: S. S. probe, PU tubing with easily detachable connectors, water separator cum filter, disposable particulate fine filter.

J. Rating Temperature: 5 t0 450 C

K. Power supply: 230 V + 10% 12 V Battery

L. Dimensions & Weight: 340 x 240 x 130 mm, 4 kg
 

 
DUAL FUEL ENGINE TEST BED (Petrol / LPG)
 
The Test Rig Consists of the following:

A. Engine: Single cylinder 4 stroke petrol engine of 100 CC capacity.
Make : Bajaj Auto Ltd./ Birla Yamaha / Equivalent

B. Dynamometer: The Engine is coupled to Electric Dynamometer.

C. Fuel Measuring Device: Fuel tank mounted on sturdy iron stand, burette tube, three way cock, connecting tube & a stop clock.

D. Calorimeter: Shell & Tube Heat Exchanger to measure the heat goes through exhaust gases.

E. Air Intake Measurement: Air Intake reservoir of size 0.3 x 0.3 x 0.5 m. with orifice plate, U-Tube manometer of 0.3 m height for the measurement of air flow rate.

F. 12 channel Digital Temperature Indicator: With set of thermocouples (six) along with 6 way selector. switch.

G. A separate arrangement is done for gas input & its measurement through rotameter

H. 12 channel Digital Temperature Indicator : With thermocouples.
 
 
VALVE TIMING DIAGRAM TWO STROKE PETROL ENGINE
 

 
VALVE TIMING DIAGRAM FOUR STROKE PETROL ENGINE TEST RIG
 

 
SINGLE CYLINDER 4 STROKE GASOLINE ENGINE TEST RIG
 
The Test Rig Consists of the following :
A. Engine : Single cylinder 4 stroke Gasoline engine of 2.5 HP /4 HP capacity.
Make : Birla Yamaha./Equaivalent

B. Dynamometer : The Engine is coupled to electric generator of 4 HP with loading device as a lamp load bank.

C. Fuel Measuring Device : Digital Fuel Measurement

D. Calorimeter : Double Pipe Heat Exchanger to measure the heat goes through exhaust gases.

E. Air Intake Measurement : Air Intake reservoir of size 0.3 x 0.3 x 0.5 m. with orifice plate, U-Tube manometer of 0.3 m height for the measurement of air flow rate.

F. 12 channel Digital Temperature Indicator: With set of thermocouples ( six ) along with 6 way selector. switch.
 

 
LPG / CNG KIT STANDARD KIT
 
with all accessories suitable for 4-wheeler of min.30kg. Capacity
 
Address: DATACONE ENGINEERS PVT. LTD.
271, `Samrajya’, Near Sangliwadi High School, Sangliwadi,
SANGLI - 416416. Maharashtra, INDIA.
Tel. No.: +91 - 233 - 2535197, 2535759, 2535841, 2850851
Fax: +91 - 233 - 2535769
Cell: +91 - 94220 40681, 97646 79181
Visit Also : www.dataconeequip.com, www.refrigerationandairconditioninglaboratory.com, www.thermodynamicslaboratory.com , www.fluidmechanicslaboratory.com, www.heattransferlaboratory.com